U1381 | U 1389 | U1387 | U1289 | U1281 | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Item number | U1381 | U1389 | U1387 | U1289 | U1281 | |||||
Product details page | Details | Details | Details | Details | Details | |||||
Pulse output | None (only with bus connection) | Electrical | None (only with bus connection) | Electrical | None (only with bus connection) | Electrical | None (only with bus connection) | Electrical | None (only with bus connection) | Electrical |
Interpulse period | > 30 ms | > 30 ms | > 30 ms | > 30 ms | > 30 ms | |||||
Relative humidity | < 75% annual average | < 75% annual average | < 75% annual average | < 75% annual average | < 75% annual average | |||||
Interference emission | EN 55022: Class B | EN 55022: Class B | EN 55022: Class B | EN 55022: Class B | EN 55022: Class B | |||||
Burst | 2 kV | 2 kV | 2 kV | 2 kV | 2 kV | |||||
Chapter06 | Overload capacity | Overload capacity | Overload capacity | Overload capacity | Overload capacity | |||||
Sampling rate | Continuous, 32 per period | Continuous, 32 per period | Continuous, 32 per period | Continuous, 32 per period | Continuous, 32 per period | |||||
Protection | IP 20 | IP 20 | IP 20 | IP 20 | IP 20 | |||||
Power consumption | Voltage path, total including supply: < 2 VA | Voltage path, total including supply: < 2 VA | Voltage path, total including supply: < 2 VA | Voltage path, total including supply: < 2 VA | Voltage path, total including supply: < 2 VA | |||||
Rated insulation voltage |
Input: 300 V AC Output: Feature V1, V2: 50 V DC (S0 and bus) Output: Feature V3, V4: 230 V AC (pulse) |
Input: 300 V AC Output: Feature V1, V2: 50 V DC (S0 and bus) Output: Feature V3, V4: 230 V AC (pulse) |
Input: 300 V AC Output: Feature V3, V4: 230 V AC (pulse) Output: Feature V1, V2: 50 V DC (S0 and bus) |
|||||||
Material | Lexan polycarbonate per UL94 V0 | Lexan polycarbonate per UL94 V0 | Lexan polycarbonate per UL94 V0 | Lexan polycarbonate per UL94 V0 | Lexan polycarbonate per UL94 V0 | |||||
Chapter02 | LCD | LCD | LCD | LCD | LCD | |||||
Limit frequency | 45Hz - 65Hz | 45Hz - 65Hz | 45Hz - 65Hz | 45Hz - 65Hz | 45Hz - 65Hz | |||||
Pulse output U(ext) | Max. 40 V (375 V with feature V3,V4) | Max. 40 V (375 V with feature V3,V4) | Max. 40 V (375 V with feature V3,V4) | Max. 40 V (375 V with feature V3,V4) | Max. 40 V (375 V with feature V3,V4) | |||||
Chapter08 | Pulse output | Pulse output | Pulse output | Pulse output | Pulse output | |||||
Minimum current rating (Imin) | 0.01A | 0.01A | 0.01A | 0.1A | 0.1A | |||||
Voltage input | ≤ 2,5mm sq. mm with wire end ferrule or ≤ 2 x 1.5 sq. mm without wire end ferrule | ≤ 2,5mm sq. mm with wire end ferrule or ≤ 2 x 1.5 sq. mm without wire end ferrule | ≤ 2,5mm sq. mm with wire end ferrule or ≤ 2 x 1.5 sq. mm without wire end ferrule | ≤ 2,5mm sq. mm with wire end ferrule or ≤ 2 x 1.5 sq. mm without wire end ferrule | ≤ 2,5mm sq. mm with wire end ferrule or ≤ 2 x 1.5 sq. mm without wire end ferrule | |||||
Display range | 0Bit - 9999999Bit | 0Bit - 9999999Bit | 0Bit - 9999999Bit | 0Bit - 9999999Bit | 0Bit - 9999999Bit | |||||
Pulse duration | 30 ms | 30 ms | 30 ms | 30 ms | 30 ms | |||||
Max. altitude | 2000m | 2000m | 2000m | 2000m | 2000m | |||||
Weight | < 0.5 kg | < 0.5 kg | < 0.5 kg | < 0.5 kg | < 0.5 kg | |||||
Interface / bus connection |
LON M-Bus L-Bus |
LON L-Bus M-Bus |
L-Bus M-Bus LON |
LON |
LON M-Bus L-Bus |
|||||
Chapter10 | Mechanical data | Mechanical data | Mechanical data | Mechanical data | Mechanical data | |||||
Type | 7-segment characters | 7-segment characters | 7-segment characters | 7-segment characters | 7-segment characters | |||||
Chapter05 | Electrical safety | Electrical safety | Electrical safety | Electrical safety | Electrical safety | |||||
Chapter07 | EMC | EMC | EMC | EMC | EMC | |||||
Protection class | II | II | II | II | II | |||||
Phase sequence/phase | Blinks in case of error | Blinks in case of error | Blinks in case of error | Blinks in case of error | Blinks in case of error | |||||
Chapter04 | Power consumption | Power consumption | Power consumption | Power consumption | Power consumption | |||||
So pulse output, �, tariff input | ≤ 2,5mm sq. mm with wire end ferrule or ≤ 2 x 1.5 sq. mm without wire end ferrule | ≤ 2,5mm sq. mm with wire end ferrule or ≤ 2 x 1.5 sq. mm without wire end ferrule | ≤ 2,5mm sq. mm with wire end ferrule or ≤ 2 x 1.5 sq. mm without wire end ferrule | ≤ 2,5mm sq. mm with wire end ferrule or ≤ 2 x 1.5 sq. mm without wire end ferrule | ≤ 2,5mm sq. mm with wire end ferrule or ≤ 2 x 1.5 sq. mm without wire end ferrule | |||||
Accuracy of reactive energy | 2 | 2 | 2 | 2 | 2 | |||||
Conducted interference | 10 V | 10 V | 10 V | 10 V | 10 V | |||||
Operation site | Indoors | Indoors | Indoors | Indoors | Indoors | |||||
Surge voltage | 6kV, 1,2/50µs 10+/10- surges | 6kV, 1,2/50µs 10+/10- surges | 6kV, 1,2/50µs 10+/10- surges | 6kV, 1,2/50µs 10+/10- surges | 6kV, 1,2/50µs 10+/10- surges | |||||
Magnetic field and line frequency | 0.5 mT | 0.5 mT | 0.5 mT | |||||||
Display refresh | Approx. 6 s | Approx. 6 s | Approx. 6 s | Approx. 6 s | Approx. 6 s | |||||
Chapter09 | Ambient conditions | Ambient conditions | Ambient conditions | Ambient conditions | Ambient conditions | |||||
Chapter01 | Measuring ranges | Measuring ranges | Measuring ranges | Measuring ranges | Measuring ranges | |||||
Chapter03 | Power supply | Power supply | Power supply | Power supply | Power supply | |||||
Starting current | 2mA | 2mA | 2mA | 20mA | 20mA | |||||
Electrostatic discharge | 15 kV | 15 kV | 15 kV | 15 kV | 15 kV | |||||
Main display | 7-place, height: 6 mm | 7-place, height: 6 mm | 7-place, height: 6 mm | 7-place, height: 6 mm | 7-place, height: 6 mm | |||||
Voltage path |
2/3-wire meter: < 2 VA 4-wire meter: < 1 VA per phase (including supply power) |
2/3-wire meter: < 2 VA 4-wire meter: < 1 VA per phase (including supply power) |
2/3-wire meter: < 2 VA 4-wire meter: < 1 VA per phase (including supply power) |
|||||||
Permissible deviation | -0,75 | -0,75 | -0,75 | -0,75 | -0,75 | |||||
Pulse run generator constants | With transformer connection: 1000 pulses per kWh | With transformer connection: 1000 pulses per kWh | With transformer connection: 1000 pulses per kWh | With direct connection: 1000 pulses per kWh | With direct connection: 1000 pulses per kWh | |||||
Reference current (Iref) | 1A | 1A | 1A | 5A | 5A | |||||
Dimensions (W x H x D) |
Height: ≤ 90mm Overall depth: ≤75 mm Width: 125.5 +0.5 mm |
Height: ≤ 90mm Overall depth: ≤75 mm Width: 125.5 +0.5 mm |
Height: ≤ 90mm Overall depth: ≤75 mm Width: 125.5 +0.5 mm |
|||||||
Mounting type | Top-hat rail per DIN EN 50022 or wall mounting | Top-hat rail per DIN EN 50022 or wall mounting | Top-hat rail per DIN EN 50022 or wall mounting | Top-hat rail per DIN EN 50022 or wall mounting | Top-hat rail per DIN EN 50022 or wall mounting | |||||
External supply |
Auxiliary voltage: 24 V ± 10% Current consumption: < 1 W |
Auxiliary voltage: 24 V ± 10% Current consumption: < 1 W |
Auxiliary voltage: 24 V ± 10% Current consumption: < 1 W |
|||||||
Switching current | Max. 27 mA (100 mA with feature V3, V4) | Max. 27 mA (100 mA with feature V3, V4) | Max. 27 mA (100 mA with feature V3, V4) | Max. 27 mA (100 mA with feature V3, V4) | Max. 27 mA (100 mA with feature V3, V4) | |||||
Insulation test current |
Input <-> output / housing: 4 kV AC Output <-> housing: Feature V1, V2: 500 V (S0 and bus) Output <-> housing: Feature V3, V4: 4 kV (pulse) |
Input <-> output / housing: 4 kV AC Output <-> housing: Feature V1, V2: 500 V (S0 and bus) Output <-> housing: Feature V3, V4: 4 kV (pulse) |
Input <-> output / housing: 4 kV AC Output <-> housing: Feature V1, V2: 500 V (S0 and bus) Output <-> housing: Feature V3, V4: 4 kV (pulse) |
|||||||
Auxiliary display | 8-place, height: 5�mm | 8-place, height: 5�mm | 8-place, height: 5�mm | 8-place, height: 5�mm | 8-place, height: 5�mm | |||||
Overload capacity |
All meters: Continuous, 1.15 Ur and Imax Current transformer connection: 0.5 s 20 x Imax Current transformer connection: continuous,10 x Imax |
All meters: Continuous, 1.15 Ur and Imax Direct connection: 5 x 3 sec.: Ur and 100 A (interval: 5 min.) Direct connection: 5 x 3 sec.: 1 x 1 sec.: Ur and 250 A |
All meters: Continuous, 1.15 Ur and Imax Direct connection: 5 x 3 sec.: Ur and 100 A (interval: 5 min.) Direct connection: 5 x 3 sec.: 1 x 1 sec.: Ur and 250 A |
|||||||
Storage temperature | -25°C - 70°C | -25°C - 70°C | -25°C - 70°C | -25°C - 70°C | -25°C - 70°C | |||||
Current input | Solid wire ≤ 16 sq. mm, without wire end ferrule | Solid wire ≤ 16 sq. mm, without wire end ferrule | Solid wire ≤ 16 sq. mm, without wire end ferrule | Solid wire ≤ 16 sq. mm, without wire end ferrule | Solid wire ≤ 16 sq. mm, without wire end ferrule | |||||
Internal power supply | 80 to 115% Ur | 80 to 115% Ur | 80 to 115% Ur | 80 to 115% Ur | 80 to 115% Ur | |||||
Electrostatic fields |
10 V/m under load 30 V/m at idle |
10 V/m under load 30 V/m at idle |
10 V/m under load 30 V/m at idle |
|||||||
Power consumption per current path |
Where Imax < 0.03 VA (transformer) Where Iref < 0.001 VA (transformer) |
At Imax: < 1 VA (direct) Where Iref < 0.02 VA (direct) |
Where Imax < 1 VA (direct) Where Iref < 0.02 VA (direct) |
|||||||
Error message | Highlighted in color for severe errors | Highlighted in color for severe errors | Highlighted in color for severe errors | Highlighted in color for severe errors | ||||||
Operating temperature range | -25°C - 55°C | -25°C - 55°C | -25°C - 55°C | -25°C - 55°C | -25°C - 55°C | |||||
Type of meter | Electronic | Electronic | Electronic | Electronic | Electronic | |||||
Nominal current (In) | 6A | 6A | 6A | 65A | 65A | |||||
Max. current (Imax) | 6A | 6A | 6A | 65A | 65A | |||||
Nominal voltage (Un) N-L | 100V - 500V | 100V - 500V | 100V - 500V | 100V - 500V | 100V - 500V | |||||
Nominal voltage (Un) L-L | 100V - 400V | 100V - 500V | ||||||||
Frequency | ||||||||||
Accuracy class | B | B | B | B | B | |||||
Pole type | Not applicable | Not applicable | Not applicable | Not applicable | Not applicable | |||||
Model | Measurement transformer | Measurement transformer | Measurement transformer | Direct measurement | Direct measurement | |||||
Energy type | Blind power | Blind power | Blind power | Effective power and blind power | Effective power and blind power | |||||
Suitable for | Purchase | Purchase | Purchase | Purchase | Purchase | |||||
Tariff type | Multi-tariff | Multi-tariff | Multi-tariff | Multi-tariff | Multi-tariff | |||||
Measuring type load profile | ||||||||||
Escapement mechanism | ||||||||||
Calibrated | x | x | x | x | x | |||||
Approval | Measuring Instruments Directive | Measuring Instruments Directive | Measuring Instruments Directive | Measuring Instruments Directive | Measuring Instruments Directive | |||||
Pulse type | S0 | S0 | S0 | S0 | S0 | |||||
Pulse rate | 1Imp/kWh (kvarh) - 10000Imp/kWh (kvarh) | 1Imp/kWh (kvarh) - 10000Imp/kWh (kvarh) | 1Imp/kWh (kvarh) - 10000Imp/kWh (kvarh) | 1Imp/kWh (kvarh) - 1000Imp/kWh (kvarh) | 1Imp/kWh (kvarh) - 1000Imp/kWh (kvarh) | |||||
Type of indication | Digital | Digital | Digital | Digital | Digital | |||||
Width in number of modular spacings | 7 | 7 | 7 | 7 | ||||||
Type of interface | LON bus | LON bus | LON bus | LON bus | LON bus | |||||
EEC40 signature | ||||||||||
With lock code | ||||||||||
Degree of protection (IP) | Other | Other | Other | Other | Other | |||||
Tariff control | Internal/external | Internal/external | ||||||||
Number of positions total (counter) | 3 |